范文编号:SP098 范文字数:7012,页数:16 摘 要:本文采用氢化物发生—原子荧光光谱法测定调味料中的铅含量,通过实验考察了载流的酸度,溶液的酸度,铁氰化钾的浓度,还原剂的浓度对铅荧光强度的不同影响,得出最佳实验条件。并在最佳实验条件下对进行回收率、精密度、准确度实验和样品分析,得出该方法的检出限为0.0031μg/L,标准曲线相关系数:0.9921,相对标准偏差小于10 %,回收率为81.7%~88.0%,采用氢化物发生—原子荧光光谱法测定调味料中的铅含量标准曲线的相关系数好, 灵敏度高, 结果准确、可靠, 且分析成本低廉, 操作简单,前景广阔。 关键词:氢化物;原子荧光光谱法;铅 Abstract: In this dissertation , the lead content was determinned hydride atomic fluorescence spectrometry .,we explored the Pb fluorescence intensity influential factors such as currentcarrying acidity , acidity of solution , concerntration of red potassium prussiate,concerntration of reducer , and proposed the optimal experiment condition .Then recovery ,precision accuracy experiments have been investigated , also the sample have been analyzed under the optimal experiment condition , the detection limit is 0.0031μg/L , the correlation coefficient is 0.9921 , standard deviation is less than 10% , the coefficient of recovery is between 81.7%—88.0% . Hydride atomic fluorescence spectrometry has some advantages when determined the lead content such as good correlation coefficient , high sensitivity , exact result , low cost and easily to handle , also it is wide prospect. Keywords:Hydride ; Atomic fluorescence spectrometry ; Lead 目 录
|